Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/50791
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sopis Chuekachang | en_US |
dc.contributor.author | Viruntachar Kruefu | en_US |
dc.contributor.author | Suwan Chaiyasit | en_US |
dc.contributor.author | Sukon Phanichphant | en_US |
dc.date.accessioned | 2018-09-04T04:45:39Z | - |
dc.date.available | 2018-09-04T04:45:39Z | - |
dc.date.issued | 2010-11-29 | en_US |
dc.identifier.other | 2-s2.0-78649268608 | en_US |
dc.identifier.other | 10.1109/NEMS.2010.5592167 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=78649268608&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/50791 | - |
dc.description.abstract | In this research, a glassy carbon electrode modified with single-wall carbon nanotubes for electrochemical determination of dopamine was studied by cyclicvoltammetry (CV) and differential pulse voltammetry (DPV). The oxidation and reduction potentials of dopamine using voltammetric technique were measured. The SWCNTs/GC 10 μL was used to test the linearity of anodic oxidation of dopamine by DPV. The peak current increased linearly with concentration of dopamine in the range of 2.5-25 ppm (R2=0.9766).For the life time of the SWCNTs/GC, the cut-off criterion of the DPV was detected in the reduction of current by 50 %. The lifetime of the SWCNTsmodified depended on the oxidation of dopamine because of fouling of the electrode surface due to the adsorption of oxidation products. 34 repetition cycles was obtained. The detection limit of the dopamine as obtained from the oxidation current in DPV was 0.021 ppm (S/N=3) with minimum current for the detection of dopamine of 0.033 μA. The reproducibility of electrocatalytical studies was better within 90% (10% RSD). The relative standard deviation (RSD) of 8.42% for 100 ppm dopamine (n=20) showed excellent reproducibility. Drug samples obtained from Radvitee hospital were tested as the mentioned procedure. The percentage recovery of dopamine in drug samples was 120. ©2010 IEEE. | en_US |
dc.subject | Engineering | en_US |
dc.title | Single-wall carbon nanotube modified glassy carbon electrode for electroanalytical determination of dopamine | en_US |
dc.type | Conference Proceeding | en_US |
article.title.sourcetitle | 2010 IEEE 5th International Conference on Nano/Micro Engineered and Molecular Systems, NEMS 2010 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | King Mongkut's Institute of Technology Ladkrabang | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.