Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/53341
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWilaiwan Phakthongen_US
dc.contributor.authorBoonsom Liawruangrathen_US
dc.contributor.authorSaisunee Liawruangrathen_US
dc.date.accessioned2018-09-04T09:47:21Z-
dc.date.available2018-09-04T09:47:21Z-
dc.date.issued2014-12-01en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84907375408en_US
dc.identifier.other10.1016/j.talanta.2014.06.024en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84907375408&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/53341-
dc.description.abstractA reversed flow injection (rFI) system was designed and constructed for gallic acid determination. Gallic acid was determined based on the formation of chromogen between gallic acid and rhodanine, resulting in a colored product with a λmaxat 520 nm. The optimum conditions for determining gallic acid were also investigated. Optimizations of the experimental conditions were carried out based on the so-call univariate method. The conditions obtained were 0.6% (w/v) rhodanine, 70% (v/v) ethanol, 0.9 mol L-1NaOH, 2.0 mL min-1flow rate, 75 μL injection loop and 600 cm mixing tubing length, respectively. Comparative optimizations of the experimental conditions were also carried out by multivariate or simplex optimization method. The conditions obtained were 1.2% (w/v) rhodanine, 70% (v/v) ethanol, 1.2 mol L-1NaOH, flow rate 2.5 mL min-1, 75 μL injection loop and 600 cm mixing tubing length, respectively. It was found that the optimum conditions obtained by the former optimization method were mostly similar to those obtained by the latter method. The linear relationship between peak height and the concentration of gallic acid was obtained over the range of 0.1-35.0 mg L-1with the detection limit 0.081 mg L-1. The relative standard deviations were found to be in the ranges 0.46-1.96% for 1, 10, 30 mg L-1of gallic acid (n=11). The method has the advantages of simplicity extremely high selectivity and high precision. The proposed method was successfully applied to the determination of gallic acid in longan samples without interferent effects from other common phenolic compounds that might be present in the longan samples collected in northern Thailand. © 2014 Elsevier B.V. All rights reserved.en_US
dc.subjectChemistryen_US
dc.titleDetermination of gallic acid with rhodanine by reverse flow injection analysis using simplex optimizationen_US
dc.typeJournalen_US
article.title.sourcetitleTalantaen_US
article.volume130en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.