Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/74464
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Thamarath Chantadansuwan | en_US |
dc.contributor.author | Jayanton Patumanond | en_US |
dc.contributor.author | Thammanard Charernboon | en_US |
dc.contributor.author | Dilok Piyayotai | en_US |
dc.date.accessioned | 2022-10-16T06:42:58Z | - |
dc.date.available | 2022-10-16T06:42:58Z | - |
dc.date.issued | 2022-09-01 | en_US |
dc.identifier.issn | 20754418 | en_US |
dc.identifier.other | 2-s2.0-85138663880 | en_US |
dc.identifier.other | 10.3390/diagnostics12092076 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85138663880&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/74464 | - |
dc.description.abstract | Direct intracoronary adenosine bolus is an excellent alternative to intravenous adenosine fractional flow reserve (FFR) measurement. This study, during four increasing adenosine boluses (50, 100, 150, and 200 mcg), aimed to explore clinical and angiographic predictors of coronary stenotic lesions for which the significant ischemic FFR (FFR ≤ 0.8) occurred at 150 and 200 mcg adenosine doses. Data from 1055 coronary lesions that underwent FFR measurement at the Central Chest Institute of Thailand from August 2011 to July 2021 were included. Baseline clinical and angiographic characteristics were analyzed. The FFR ≤ 0.8 occurred at adenosine 150 and 200 mcg boluses in 47 coronary lesions, while the FFR ≤ 0.8 occurred at adenosine 50 and 100 mcg boluses in 186 coronary lesions. After univariable and multivariable logistic regression analyses, four characteristics, including male sex, younger age, non-smoking status, and FFR procedure of RCA, were predictors of the occurrence of FFR ≤ 0.8 at adenosine 150 and 200 mcg doses. Combining all four predictors as a predictive model resulted in an AuROC of 0.72 (95% CI: 0.68–0.76), an 86% negative predictive value. Comparing these four predictors, the FFR procedure of RCA gave the most predictive power, with the AuROC of 0.60 (95% CI: 0.56–0.63). | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | Factors Predicting 150 and 200 Microgram Adenosine Requirement during Four Increasing Doses of Intracoronary Adenosine Bolus Fractional Flow Reserve Assessment | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Diagnostics | en_US |
article.volume | 12 | en_US |
article.stream.affiliations | Faculty of Medicine, Chiang Mai University | en_US |
article.stream.affiliations | Faculty of Medicine, Thammasat University | en_US |
article.stream.affiliations | Central Chest Institute of Thailand | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.